PRODUCTS · REVOLUTION SAMPLE PREP

Revolution Plus System and Kits

Flexible liquid biopsy sample preparation across a broad range of analytes, sample types, and input volumes.

Revolution Plus supports cell-free nucleic acid extraction and CTC enrichment using the appropriate kit and single-use nRicher Cartridge. Its semi-automated workflow combines instrument processing with operator-performed steps.

PART NUMBER PN 2000-PLUS
SYSTEM Revolution Plus
WORKFLOW Semi-Automated
nRichDX Revolution Plus Sample Prep System
01
CELL-FREE ANALYTES Up to 50 mL
02
CTC ENRICHMENT Dedicated RUO Kits
Analytes cfDNA · cfRNA · cfTNA · CTCs
Sample Types Plasma · Urine · Blood · Other Fluids
Cell-Free Input Up to 50 mL
Workflow Foundation nRicher Cartridge
SEMI-AUTOMATED WORKFLOWS

Revolution Plus.
Your choice of wash and elution workflow.

Use Revolution Plus with manual wash and elution, or transfer samples to Hamilton STAR for automated wash and elution in supported workflows. Both configurations are semi-automated.

The Hamilton configuration includes operator involvement during Plus processing and a manual transfer to Hamilton STAR.

Explore Hamilton Workflows
Revolution PlusRevolution Plus
Operator
transfer
Hamilton STARHamilton STAR
Plus processing → Operator transfer → Automated wash and elution
nRichDX nRicher Cartridge
THE RECOVERY FOUNDATION Single-use nRicher Cartridge
BUILT AROUND RECOVERY

The nRicher Cartridge is at the center of the Revolution workflow.

The patented Revolution technology combines extraction, enrichment, and concentration in a single-use cartridge architecture.

By reducing the need for yield-lowering sample transfers, re-elutions, and pooling multiple extractions from the same sample, Revolution Plus is designed to handle both small- and large-volume sample preparation workflows.

01

Integrated Processing

Extraction, enrichment, and concentration are brought together within the cartridge-based workflow.

03

Broad Sample Range

Supports liquid biopsy workflows across plasma, urine, blood, and other bodily fluids.

04

Volume Flexibility

Supports cell-free analyte inputs up to 50 mL and larger-volume CTC and other application workflows.

TWO OPERATING MODES

Standardized kit workflows or user-programmable research flexibility.

Revolution Plus operates in two different modes using separate USB keys, allowing laboratories to move between approved kit protocols and research workflow development.

02 RESEARCH MODE

User-Programmable Operation

Research Mode is available separately and provides user-programmable operation for research workflow development.

Available Separately · RUO
Revolution Plus Kit Mode and Research Mode interface
REVOLUTION PLUS INTERFACE Kit Mode + Research Mode
REVOLUTION KIT PORTFOLIO

Match the kit to your analyte and input volume.

Revolution kits pair analyte-specific reagents with nRicher Cartridges sized for the intended sample-volume range. Reagent-only kits are also available for utilization of excess cartridges where noted.

IVD · cfDNA Revolution cfDNA Max 20 Kit

Revolution cfDNA Max 20 Kit

PN 408000
Input Volume
1–20 mL
Starting Samples
Blood, Plasma, Urine, CSF
nRicher Cartridges
24
List Price
$600 USD
View Kit Details
IVD · cfDNA Revolution cfDNA Max 50 Kit

Revolution cfDNA Max 50 Kit

PN 405000
Input Volume
>20–50 mL
Starting Samples
Blood, Plasma, Urine, CSF
nRicher Cartridges
24
List Price
$1,995 USD
View Kit Details
IVD · cfTNA / cfRNA Revolution cfTNA Max 20 Kit

Revolution cfTNA Max 20 Kit

PN 408500
Input Volume
1–20 mL
Starting Samples
Blood, Plasma, Urine
nRicher Cartridges
24
List Price
$600 USD
View Kit Details
COMING SOON · cfTNA / cfRNA Revolution cfTNA Max 50 Kit

Revolution cfTNA Max 50 Kit

PN 406500
Input Volume
>20–50 mL
Starting Samples
Blood, Plasma, Urine
nRicher Cartridges
24
List Price
$1,995 USD
View Kit Details
RUO · CTC Revolution CTC Enrichment Kit

Revolution CTC Enrichment Kit

PN 407000
Input Volume
1–50 mL*
Starting Sample
Whole Blood
nRicher Cartridges
12
List Price
$1,788 USD
View Kit Details
? NEED HELP CHOOSING?

Find the kit that fits your workflow.

Filter the Revolution portfolio by analyte, sample type, and input sample volume.

Open Kit Selector
KIT DETAILS

Revolution kit configurations

Open each kit family below for included components, extraction capacity, reagent-only options, and available resources.

cfDNA · 1–20 mL Revolution cfDNA Max 20 Kits IVD · PN 408000 / 401000
Revolution cfDNA Max 20 Kit open box
COMPLETE KIT

Revolution cfDNA Max 20 Kit

PN 408000 · $600 USD

For input sample volumes such as plasma and urine from 1 mL–20 mL. Includes nRicher Cartridges and kit reagents.

Kit includes 24 × 50 mL nRicher Cartridges and sufficient reagents for:
24 × 1–5 mL 12 × 6–10 mL 8 × 11–15 mL 6 × 16–20 mL

Eluted nucleic acid is suitable for NGS, PCR, and other downstream molecular biology assays.

REAGENT-ONLY OPTION

Revolution cfDNA Max 20 Reagent Kit

PN 401000 · $480 USD. Supplemental reagents for use with excess cfDNA Max 20 nRicher Cartridges. nRicher Cartridges are not included.

cfDNA · >20–50 mL Revolution cfDNA Max 50 Kits IVD · PN 405000 / 404000
Revolution cfDNA Max 50 Kit open box
COMPLETE KIT

Revolution cfDNA Max 50 Kit

PN 405000 · $1,995 USD

Designed for larger input sample volumes greater than 20 mL through 50 mL. Includes nRicher Cartridges and kit reagents.

Kit includes 24 × 100 mL nRicher Cartridges and sufficient reagents for:
24 × 21–30 mL 18 × 31–40 mL 12 × 41–50 mL

Eluted nucleic acid is suitable for NGS, PCR, and other downstream molecular biology assays.

REAGENT-ONLY OPTION

Revolution cfDNA Max 50 Reagent Kit

PN 404000 · $1,875 USD. Supplemental reagents for use with excess cfDNA Max 50 nRicher Cartridges. nRicher Cartridges are not included.

cfTNA / cfRNA · 1–20 mL Revolution cfTNA Max 20 Kits IVD · PN 408500 / 401500
Revolution cfTNA Max 20 Kit
COMPLETE KIT

Revolution cfTNA Max 20 Kit

PN 408500 · $600 USD

For input sample volumes such as plasma and urine from 1 mL–20 mL. The kit may be used to isolate circulating cell-free total nucleic acid (cfTNA) or cfRNA using an optional DNase digestion step.

Kit includes 24 nRicher Cartridges and sufficient reagents for:
24 × 1–5 mL 12 × 6–10 mL 8 × 11–15 mL 6 × 16–20 mL

Eluted nucleic acid is suitable for NGS, PCR, and other downstream molecular biology assays.

REAGENT-ONLY OPTION

Revolution cfTNA Max 20 Reagent Kit

PN 401500 · $480 USD. Supplemental reagents for use with excess cfTNA Max 20 nRicher Cartridges. nRicher Cartridges are not included.

cfTNA / cfRNA · >20–50 mL Revolution cfTNA Max 50 Kits COMING SOON · PN 406500 / 405500
Revolution cfTNA Max 50 Kit
COMPLETE KIT · COMING SOON

Revolution cfTNA Max 50 Kit

PN 406500 · $1,995 USD

Designed for larger input sample volumes greater than 20 mL through 50 mL. Includes nRicher Cartridges and kit reagents.

Kit includes 24 × 100 mL nRicher Cartridges and sufficient reagents for:
24 × 21–30 mL 18 × 31–40 mL 12 × 41–50 mL

Eluted nucleic acid is suitable for NGS, PCR, and other downstream molecular biology assays.

REAGENT-ONLY OPTION · COMING SOON

Revolution cfTNA Max 50 Reagent Kit

PN 405500 · $1,875 USD. Supplemental reagents for use with excess cfTNA Max 50 nRicher Cartridges. nRicher Cartridges are not included.

CTCs · Whole Blood Revolution CTC Kits RUO · PN 407000 / 407600
Revolution CTC Enrichment Kit open box
ENRICHMENT KIT · RUO

Revolution CTC Enrichment Kit (Epithelial Origin)

PN 407000 · $1,788 USD

Uses proprietary magnetic beads and anti-EpCAM antibodies to isolate intact, viable epithelial-derived circulating tumor cells from whole blood.

Includes reagents and 12 × 50 mL nRicher Cartridges for CTC isolation from RBC + Buffy Coat fractions of whole blood:
12 × 10 mL 6 × 20 mL 3 × 40 mL

Supports CTC enrichment from 1 mL up to 50 mL in a single extraction. Inquire about larger sample volumes up to 100 mL per extraction.

For Research Use Only. Not for use in diagnostic procedures.
REAGENT-ONLY OPTION · RUO

Revolution CTC Reagent Kit

PN 407600 · $1,728 USD. Supplemental CTC enrichment reagents for complete utilization of unused cartridges from the CTC Enrichment Kit. nRicher Cartridges are not included.

Reagent volumes support 12 CTC isolations of up to 10 mL of sample per nRicher Cartridge.

PRODUCT LABELING

Know the intended-use labeling for each workflow.

The Revolution Plus Sample Prep System is IVD-labeled. Revolution cfDNA and cfTNA kits, when used in Kit Mode on the Revolution Plus instrument, are IVD-labeled. The Revolution CTC Enrichment Kit (Epithelial Origin) and Revolution CTC Reagent Kit are labeled for Research Use Only and are not for use in diagnostic procedures.

BUILD YOUR REVOLUTION WORKFLOW

Talk with us about your analyte, sample type, and input volume.